Liquid reservoir BLR/VLRD-08
Vertical fluid reservoir (volume 8l)
SKU: | BLR/VLRD-08 |
Availability: | out of stock |
Price inc VAT: | 195.42 zł 325.70 zł |
Price netto: | 158.88 zł 264.8 zł |
Your discount on this product: | 40 % |
You do not have an account? Register and
shop with discounts for professionals!
Color [Ral] | 5009 |
General tolerances [mm] | / -3 |
Dimensions (see drawing) | D: ф180mm L: 370mm A: 80mm |
Volume | 8 liters |
Test pressure [PT] | 48 bar |
The diameter of the mounting flange | 187mm |
Connection | 1/2 "ODS |
Safety valve and sight glass | upon request |
Departure | 1/2 "ODS Rotolock valve |
Permissible temperature | min. -10 ° C / max. -120 ° C |
Working pressure [PS] | 33 bar |
The vertical liquid tank BLR/VLRD-08 with a capacity of 8 liters makes it possible to protect the refrigeration system against the constantly changing demand for refrigerant, thanks to which the correct circulation of the refrigerant in the system is possible. The liquid tank is made of steel and has a Rotolock valve that allows you to service the refrigeration system without the need to remove the refrigerant from the system.
All registered trademarks and trademarks are the property of their respective owners.
Proper names are provided for information purposes only and are used to compare the products.
Product Liquid reservoir BLR/VLRD-08 belongs to the category Pressure products and subcategories Liquid receivers
Pressure products are essential components of refrigeration and air conditioning systems. Filter driers protect all parts of the refrigeration and air conditioning system against contamination and moisture (Remember to change the filter driers regularly!). Other: oil separators and filters, liquid accumulators, vessels and vibration absorbers on the pressure system enable proper circulation of cooling liquid, cooling gas and oil, which ensures long and trouble-free operation of the entire system. We offer a wide range of parts for the construction, maintenance and service of refrigeration and air conditioning systems. We invite you to contact manufacturers of equipment and installations, wholesalers, shops and services: refrigeration and air conditioning.
Refrigerant tanks allow the refrigerant liquid and refrigerant gas to circulate properly. These tanks are used to collect liquid refrigerant to protect the system from the constantly changing demand for refrigerant and allow it to flow evenly to the valve. The right choice of refrigerant tank is important. The size of the liquid tank should be matched to the size of the refrigeration system. The volume of the tank should be about 130% of the total amount of refrigerant (the total amount of refrigerant should take 70% of the total volume of the tank). In our offer you will find a wide selection of steel liquid tanks with a capacity of 1 to 21 liters. Each REFrigerant tank of the BLR/VLRD series has a manual Rotolock valve that allows you to service the refrigeration system without the need to remove the refrigerant.
zbiornik cieczy zbiornik czynnika chłodniczegozbiornik gazu chłodniczegozbiornik cieczy chłodniczyzbiornik cieczy klimatyzacyjnypionowy zbiornik cieczy z zaworem Rotolockpionowy zbiornik cieczy z zaworem Rotalockzbiornik cieczy z wziernikiemzbiornik cieczy z połączeniem ODSzbiornik cieczy chłodniczejpionowy zbiornik cieczy chłodniczejpionowy zbiornik czynnika chłodniczegosystemy chłodniczesystemy klimatyzacyjne- Technical data
Color [Ral]
5009
General tolerances [mm]
/ -3
Dimensions (see drawing)
D: ф180mm L: 370mm A: 80mm
Volume
8 liters
Test pressure [PT]
48 bar
The diameter of the mounting flange
187mm
Connection
1/2 "ODS
Safety valve and sight glass
upon request
Departure
1/2 "ODS Rotolock valve
Permissible temperature
min. -10 ° C / max. -120 ° C
Working pressure [PS]
33 bar
- Product description
The vertical liquid tank BLR/VLRD-08 with a capacity of 8 liters makes it possible to protect the refrigeration system against the constantly changing demand for refrigerant, thanks to which the correct circulation of the refrigerant in the system is possible. The liquid tank is made of steel and has a Rotolock valve that allows you to service the refrigeration system without the need to remove the refrigerant from the system.
- Compatibility
All registered trademarks and trademarks are the property of their respective owners.
Proper names are provided for information purposes only and are used to compare the products.
- More information
Product Liquid reservoir BLR/VLRD-08 belongs to the category Pressure products and subcategories Liquid receivers
Pressure products are essential components of refrigeration and air conditioning systems. Filter driers protect all parts of the refrigeration and air conditioning system against contamination and moisture (Remember to change the filter driers regularly!). Other: oil separators and filters, liquid accumulators, vessels and vibration absorbers on the pressure system enable proper circulation of cooling liquid, cooling gas and oil, which ensures long and trouble-free operation of the entire system. We offer a wide range of parts for the construction, maintenance and service of refrigeration and air conditioning systems. We invite you to contact manufacturers of equipment and installations, wholesalers, shops and services: refrigeration and air conditioning.
Refrigerant tanks allow the refrigerant liquid and refrigerant gas to circulate properly. These tanks are used to collect liquid refrigerant to protect the system from the constantly changing demand for refrigerant and allow it to flow evenly to the valve. The right choice of refrigerant tank is important. The size of the liquid tank should be matched to the size of the refrigeration system. The volume of the tank should be about 130% of the total amount of refrigerant (the total amount of refrigerant should take 70% of the total volume of the tank). In our offer you will find a wide selection of steel liquid tanks with a capacity of 1 to 21 liters. Each REFrigerant tank of the BLR/VLRD series has a manual Rotolock valve that allows you to service the refrigeration system without the need to remove the refrigerant.
zbiornik cieczy zbiornik czynnika chłodniczegozbiornik gazu chłodniczegozbiornik cieczy chłodniczyzbiornik cieczy klimatyzacyjnypionowy zbiornik cieczy z zaworem Rotolockpionowy zbiornik cieczy z zaworem Rotalockzbiornik cieczy z wziernikiemzbiornik cieczy z połączeniem ODSzbiornik cieczy chłodniczejpionowy zbiornik cieczy chłodniczejpionowy zbiornik czynnika chłodniczegosystemy chłodniczesystemy klimatyzacyjne
Did not find the information you are looking for?
Ask for the product